Details
HYRM Series 1st Stage Middle Pressure Redulator (Non Adjustable Type)
HYRM SERIES regulator is for the second stage first reduction system that reduces range 0.1~15.6 MPa to 0.057~0.083 MPa.
Introduce
The HYRM Series (Non adjustable) is for first stage reduction side under twice pressure reduction system.
The inlet pressure which it can handle is 14.2~221.52 Psi(0.1~1.56MPa) and reduce to 8.1~11.8 Psi (0.057~0.083MPa). Our regulator of second stage twice reduction is necessary to be connected after HYRM series for properly use of gas at useful pressure. Also, it can be used in industrial and commercial application.
HYRM series is easy to reinstall with adjusting pressure setting by equipped bolt. The compact design makes easy to install in small space.
For easy installation, the PT thread is selected. The valve seat is equipped by inlet side to control fast and precisely for variation of inlet pressure, so the safety and high performance is guaranteed.
Feature
High accuracy and fast response at max flow of gas is one of strong point and it has high strength to avoid corrosion as well as excellent durability.
*Possible to forward precise load by fabric diaphragm inside of regulator and continue to use for long time as it has low chance for deformation and damage of diaphragm.
*It is designed to minimize the freezing inside by selecting larger diameter of orifice. Easy to reinstall with adjusting pressure setting by equipped bolt. The compact design makes easy to install in small space.
HYRM Series
When it is used as first stage for 2ND reduction system, it should be checked if the inlet pressure is matched with regulator’s specifi cation.
At the condition with full of pressure for both gas cylinder, one cylinder can be selected by rotating changeover lever. The direction that appointed by lever end is the supplying cylinder and another one is reserve side.
Specification
Inlet Pressure Range (P1) : | 0.1~1.56 MPa |
---|---|
Setting Outlet Pressure (P2) : | 0.057~0.083 MPa |
Capacity : | 200 kg/h |
Lock Up Pressure : | 0.095 MPa |
Inlet Connection Size : | PT 1-1/2B |
Outlet Connection Size : | PT 1-1/2B |
Application : | Industrial |
View more about HYRM-200 on main site